BAC net is a communications protocol for Building Automation and Control (BAC) networks that leverage the ASHRAE, ANSI, and ISO 16484-5 standard protocol.

BACnet was designed to allow communication of building automation and control systems for applications such as heating, ventilating, and air-conditioning control (HVAC), lighting control, access control, and fire detection systems and their associated equipment. The BACnet protocol provides mechanisms for computerized building automation devices to exchange information, regardless of the particular building service they perform.


HVAC Plumber and Electrician Services Salt Lake City UT | ESCO ...
photo src: www.escoutah.com


Maps, Directions, and Place Reviews



History

The development of the BACnet protocol began in June, 1987, in Nashville, Tennessee, at the inaugural meeting of the ASHRAE BACnet committee, known at that time as SPC 135P, "EMCS Message Protocol". The committee worked at reaching consensus using working groups to divide up the task of creating a standard. The working groups focused on specific areas and provided information and recommendations to the main committee. The first three working groups were the Data Type and Attribute Working Group, Primitive Data Format Working Group, and the Application Services Working Group.

BACnet became ASHRAE/ANSI Standard 135 in 1995, and ISO 16484-5 in 2003. The Method of Test for Conformance to BACnet was published in 2003 as BSR/ASHRAE Standard 135.1. BACnet is under continuous maintenance by the ASHRAE Standing Standard Project Committee 135.

BACnet had an almost immediate impact on the HVAC controls industry. In 1996 Alerton announced a complete BACnet product line for HVAC controls, from the operator's workstation down to small VAV controllers. Automated Logic Corporation and Delta Controls soon followed suit. On July 12, 2017 BACnet reached a milestone with the issuance of the 1000th Vendor ID. Vendor IDs are assigned by ASHRAE and are distributed internationally. Those vendor identifiers can be viewed at the BACnet website.

H. Michael (Mike) Newman, Manager of the Computer Section of the Utilities and Energy Management Department at Cornell University, served as the BACnet committee chairman until June, 2000, when he was succeeded by his vice-chair of 13 years, Steven (Steve) Bushby from NIST.

During Steve Bushby's four-year term as committee chair the BACnet standard was republished twice, in 2001 and 2004, each time with new capabilities added to the standard. The 2001 version featured, among other things, extensions to support fire / life-safety systems.

In June, 2004, 17 years after the first BACnet meeting and back in Nashville, William (Bill) Swan (a.k.a. "BACnet Bill") from Alerton began his four-year stint as committee chair. During his term the number of committee working groups grew to 11, pursuing areas such as support for lighting, access control, energy utility/building integration and wireless communications.

In January 2006 the BACnet Manufacturers Association and the BACnet Interest Group of North America combined their operation in a new organization called BACnet International.

In June 2008, in Salt Lake City, Dave Robin from Automated Logic Corporation took over the reins as the new committee chair after serving 4 years as vice chair. During Dave's term, 22 addenda were published for the 135-2008 standard and republished as 135-2010. Several addenda were published for 135-2010 and the standard was republished as 135-2012.

In June 2012, in San Antonio, Carl Neilson from Delta Controls took over the reins as the new committee chair after serving 4 years as vice chair. During Carl's term, 12 addenda were published for the 135-2012 standard and the it was republished as 135-2016.

In June 2015, Carl stepped down as chair. Bernhard Isler, from Siemens, became chair after serving 3 years as vice chair and 4 years as secretary.


Hvac Salt Lake City Video



Protocol overview

The BACnet protocol defines a number of services that are used to communicate between building devices. The protocol services include Who-Is, I-Am, Who-Has, I-Have, which are used for Device and Object discovery. Services such as Read-Property and Write-Property are used for data sharing. As of ANSI/ASHRAE 135-2016, the BACnet protocol defines 59 object types that are acted upon by the services.

The BACnet protocol defines a number of data link / physical layers, including ARCNET, Ethernet, BACnet/IP, BACnet/IPv6, Point-To-Point over RS-232, Master-Slave/Token-Passing over RS-485, ZigBee, and LonTalk.


Our 57 Best Salt Lake City, UT HVAC Contractors | Angie's List
photo src: www.angieslist.com


BACnet objects

ANSI/ASHRAE 135-2016 specifies 60 standard object types:


Utah HVAC - HVAC Contractor - Salt Lake City, UT 84123
photo src: ezlocal.com


BACnet testing

BACnet Testing Laboratories ("BTL") was established by BACnet International to test products as per BACnet standard and support compliance testing and interoperability testing activities and consists of BTL Manager and the BTL working group ("BTL-WG"). The general activities of the BTL are:

  • Publish the BTL Implementation Guidelines document
  • Certifying the products as per BACnet testing and BTL guidelines
  • Support the activities of the BTL-WG
  • Maintain the BTL test packages
  • Approves Testing Laboratories for BTL Testing

The BTL also provides testing services through BACnet Laboratories. The BTL Managers and BTL working groups of BACnet International administer the test Laboratories. All BTL-recognized BACnet Test Organizations are ISO 17025 accredited.

In January, 2017, a new BTL certification program was announced. Under this program, the work of the BTL and WSPCert (the European BACnet certification body) is merged. This merger forms a single point of testing for both the BTL Mark and the Certificate of Conformance.

Source of the article : Wikipedia